   abstract = {This paper explains the research results of  leakage current, hydrophobicity and flashover voltage comparison on ceramics and epoxy  resin 20 kV outdoor insulator in a  chamber at tropical climate conditions. The waveform of leakage current (LC) was measured using a digital oscilloscope. The digital data was transferred to a personal computer using a RS-232 cable. The digital data was analyzed using Fast Fourier Transform. The result showed that LC was affected by various environment conditions like temperature, humidity and pollution. LC of ceramics insulator was higher than epoxy resin insulator in low temperature, high humidity and high pollution condition.},
   issn = {2088-5334},
   publisher = {INSIGHT - Indonesian Society for Knowledge and Human Development},
   url = {http://ijaseit.insightsociety.org/index.php?option=com_content&view=article&id=9&Itemid=1&article_id=100},
   doi = {10.18517/ijaseit.1.5.100}
}

EndNote

%A Yandri, Valdi Rizki
%D 2011
%T Leakage Current Phenomenon on Ceramics and Epoxy Resin as 20 kV Outdoor Insulator at Tropical Environment
%B 2011
%9 outdoor insulator, epoxy resin, leakage current, hydrophobicity, flashover voltage
%! Leakage Current Phenomenon on Ceramics and Epoxy Resin as 20 kV Outdoor Insulator at Tropical Environment
%K outdoor insulator, epoxy resin, leakage current, hydrophobicity, flashover voltage
%X This paper explains the research results of  leakage current, hydrophobicity and flashover voltage comparison on ceramics and epoxy  resin 20 kV outdoor insulator in a  chamber at tropical climate conditions. The waveform of leakage current (LC) was measured using a digital oscilloscope. The digital data was transferred to a personal computer using a RS-232 cable. The digital data was analyzed using Fast Fourier Transform. The result showed that LC was affected by various environment conditions like temperature, humidity and pollution. LC of ceramics insulator was higher than epoxy resin insulator in low temperature, high humidity and high pollution condition.
%U http://ijaseit.insightsociety.org/index.php?option=com_content&view=article&id=9&Itemid=1&article_id=100
%R doi:10.18517/ijaseit.1.5.100
%J International Journal on Advanced Science, Engineering and Information Technology
%V 1
%N 5
%@ 2088-5334

IEEE

Valdi Rizki Yandri,"Leakage Current Phenomenon on Ceramics and Epoxy Resin as 20 kV Outdoor Insulator at Tropical Environment," International Journal on Advanced Science, Engineering and Information Technology, vol. 1, no. 5, pp. 491-495, 2011. [Online]. Available: http://dx.doi.org/10.18517/ijaseit.1.5.100.

RefMan/ProCite (RIS)

TY  - JOUR
AU  - Yandri, Valdi Rizki
PY  - 2011
TI  - Leakage Current Phenomenon on Ceramics and Epoxy Resin as 20 kV Outdoor Insulator at Tropical Environment
JF  - International Journal on Advanced Science, Engineering and Information Technology; Vol. 1 (2011) No. 5
Y2  - 2011
SP  - 491
EP  - 495
SN  - 2088-5334
PB  - INSIGHT - Indonesian Society for Knowledge and Human Development
KW  - outdoor insulator, epoxy resin, leakage current, hydrophobicity, flashover voltage
N2  - This paper explains the research results of  leakage current, hydrophobicity and flashover voltage comparison on ceramics and epoxy  resin 20 kV outdoor insulator in a  chamber at tropical climate conditions. The waveform of leakage current (LC) was measured using a digital oscilloscope. The digital data was transferred to a personal computer using a RS-232 cable. The digital data was analyzed using Fast Fourier Transform. The result showed that LC was affected by various environment conditions like temperature, humidity and pollution. LC of ceramics insulator was higher than epoxy resin insulator in low temperature, high humidity and high pollution condition.
UR  - http://ijaseit.insightsociety.org/index.php?option=com_content&view=article&id=9&Itemid=1&article_id=100
DO  - 10.18517/ijaseit.1.5.100

RefWorks

RT Journal Article
ID 100
A1 Yandri, Valdi Rizki
T1 Leakage Current Phenomenon on Ceramics and Epoxy Resin as 20 kV Outdoor Insulator at Tropical Environment
JF International Journal on Advanced Science, Engineering and Information Technology
VO 1
IS 5
YR 2011
SP 491
OP 495
SN 2088-5334
PB INSIGHT - Indonesian Society for Knowledge and Human Development
K1 outdoor insulator, epoxy resin, leakage current, hydrophobicity, flashover voltage
AB This paper explains the research results of  leakage current, hydrophobicity and flashover voltage comparison on ceramics and epoxy  resin 20 kV outdoor insulator in a  chamber at tropical climate conditions. The waveform of leakage current (LC) was measured using a digital oscilloscope. The digital data was transferred to a personal computer using a RS-232 cable. The digital data was analyzed using Fast Fourier Transform. The result showed that LC was affected by various environment conditions like temperature, humidity and pollution. LC of ceramics insulator was higher than epoxy resin insulator in low temperature, high humidity and high pollution condition.
LK http://ijaseit.insightsociety.org/index.php?option=com_content&view=article&id=9&Itemid=1&article_id=100
DO  - 10.18517/ijaseit.1.5.100