Post-Stroke Rehabilitation Exosceleton Movement Control using EMG Signal

Akif Rahmatillah (1), Osmalina Nur Rahma (2), Muhammad Amin (3), Septian Indra Wicaksana (4), Khusnul Ain (5), Riries Rulaningtyas (6)
(1) Medical Instrumentation Laboratory, Biomedical Engineering Study Program, Faculty of Science and Technology, Universitas Airlangga Surabaya, Indonesia
(2) Medical Instrumentation Laboratory, Biomedical Engineering Study Program, Faculty of Science and Technology, Universitas Airlangga Surabaya, Indonesia
(3) Medical Instrumentation Laboratory, Biomedical Engineering Study Program, Faculty of Science and Technology, Universitas Airlangga Surabaya, Indonesia
(4) Medical Instrumentation Laboratory, Biomedical Engineering Study Program, Faculty of Science and Technology, Universitas Airlangga Surabaya, Indonesia
(5) Medical Instrumentation Laboratory, Biomedical Engineering Study Program, Faculty of Science and Technology, Universitas Airlangga Surabaya, Indonesia
(6) Medical Instrumentation Laboratory, Biomedical Engineering Study Program, Faculty of Science and Technology, Universitas Airlangga Surabaya, Indonesia
Fulltext View | Download
How to cite (IJASEIT) :
Rahmatillah, Akif, et al. “Post-Stroke Rehabilitation Exosceleton Movement Control Using EMG Signal”. International Journal on Advanced Science, Engineering and Information Technology, vol. 8, no. 2, Apr. 2018, pp. 616-21, doi:10.18517/ijaseit.8.2.4960.
Post-stroke rehabilitation device is very important nowadays, considering the high rate of disability caused by stroke especially arm function. About 50% of stroke survivors experience the unilateral motor deficits which decreased upper extremity function. Therefore, hand and shoulders therapy are generally performed in advance to support patients’ daily activities. Electromyograph (EMG) signals from selective muscles were proven to provide additional power for post-stroke rehabilitation device to recover more quickly because the patient participates actively in rehabilitation. This paper describes a preliminary prototype of upper limb exoskeleton for post-stroke therapy devices utilizes automatic control algorithm to control human arm movement with one degree of freedom based on a myoelectric signal of muscle biceps brachii from their unaffected side. This study used low-cost instruments and digital signal processing, such as IIR low pass filter followed by Kalman filter to generate the myoelectric signal that separated from noise as an input for controlling the DC motor which moved the exoskeleton of arm therapy mechanic. The accuracy of system performance  in this study was 95%. Hopefully, this device can help stroke survivors to perform therapy independently without depending on therapists so that rehabilitation will be more effective and efficient.

Ministry of Health, “Presiden Resmikan RS Pusat Otak Nasional,” 2014. [Online]. Available: http://www.depkes.go.id/article/view/201407200001/presiden-resmikan-rs-pusat-otak-nasional.html. [Accessed: 21-Feb-2018].

J. A. Franck, “Concise Arm and Hand Rehabilitation Approach in Stroke,” vol. 3, no. 4, 2015.

R. Song, K. Tong, X. Hu, and L. Li, “Assistive Control System Using Continuous Myoelectric Signal in Robot-Aided Arm Training for Patients After Stroke,” IEEE Trans. Neural Syst. Rehabil. Eng. (Volume16 , Issue 4 ), vol. 16, no. 4, pp. 371-379, 2008.

W. H. Chang and Y.-H. Kim, “Robot-assisted Therapy in Stroke Rehabilitation,” J. Stroke, vol. 15, no. 3, p. 174, 2013.

C. G. Burgar, P. S. Lum, P. C. Shor, and H. F. Machiel Van der Loos, “Development of robots for rehabilitation therapy: the Palo Alto VA/Stanford experience.,” J. Rehabil. Res. Dev., vol. 37, no. 6, pp. 663-73, 2000.

M. Reinvee, P. Vaas, J. Ereline, and M. Pí¤í¤suke, “Applicability of Affordable sEMG in Ergonomics Practice,” Procedia Manuf., vol. 3, no. Ahfe, pp. 4260-4265, 2015.

Olimex, “Sheild EKG-EMG - Open Source Hardware Board,” no. June, 2015.

T. Triwiyanto, O. Wahyunggoro, H. A. Nugroho, and H. Herianto, “Evaluating the performance of Kalman filter on elbow joint angle prediction based on electromyography,” Int. J. Precis. Eng. Manuf., vol. 18, no. 12, pp. 1739-1748, 2017.

M. Grewal and A. Andrews, Kalman filtering: theory and practice using MATLAB, vol. 5. 2011.

G. Welch and G. Bishop, “An Introduction to the Kalman Filter,” In Pract., vol. 7, no. 1, pp. 1-16, 2006.

Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

Authors who publish with this journal agree to the following terms:

    1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
    2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
    3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).