Robust Optimal Controller Design for Induction Generator Driven by Variable-Speed Wind Turbine with STATCOM Using Immune Algorithm

Majid Naserian (1), Abolfazl Karimi (2), Seyed Esmaeil Mirabdolahi (3)
(1) Department of Electrical Engineering, Islamic Azad University, Iran
(2) Department of Electrical Engineering, Islamic Azad University, Iran
(3) Department of Electrical Engineering, Islamic Azad University, Iran
Fulltext View | Download
How to cite (IJASEIT) :
Naserian, Majid, et al. “Robust Optimal Controller Design for Induction Generator Driven by Variable-Speed Wind Turbine With STATCOM Using Immune Algorithm”. International Journal on Advanced Science, Engineering and Information Technology, vol. 1, no. 5, Oct. 2011, pp. 481-6, doi:10.18517/ijaseit.1.5.98.
This paper presents the modelling, controller design and a steady-state analysis algorithm for a wind-driven induction generator system. An output feedback linear quadratic controller is designed for the static synchronous compensator (STATCOM) and the variable blade pitch in a wind energy conversion system (WECS) in order to reach the voltage and mechanical power control under both grid-connection and islanding conditions. A two-reference-frame model is proposed to decouple the STATCOM real and reactive power control loops for the output feedback controller. To ensure zero steady-state voltage errors for the output feedback controller, the integrals of load bus voltage deviation and dc-capacitor  voltage deviation are employed as the additional state variables. Pole-placement technique is used to determine a proper weighting matrix for the linear quadratic controller such that satisfactory damping characteristics can be achieved for the closed-loop system. Effects of various system disturbances on the dynamic performance have been simulated, and the results reveal that the proposed controller is effective in regulating the load voltage and stabilizing the generator rotating speed for the WECS either  connected with or disconnected from the power grid. In addition, proper steady-state operating points for an isolated induction generator can be determined by the proposed steady-state analysis algorithm. Constant output frequency control using the  derived steady-state characteristics of the isolated induction generator is then demonstrated in this paper.

Authors who publish with this journal agree to the following terms:

    1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
    2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
    3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).