Empirical Evaluation of Variation of Orifice Blocking Ratio in a Tuned Liquid Column Damper using Frequency Response Function Measurement

Lovely Son (1), Marshal Marshal (2), Mulyadi Bur (3)
(1) Mechanical Engineering Department, Andalas University, Kampus Limau Manis, Padang, Indonesia
(2) Mechanical Engineering Department, Andalas University, Kampus Limau Manis, Padang, Indonesia
(3) Mechanical Engineering Department, Andalas University, Kampus Limau Manis, Padang, Indonesia
Fulltext View | Download
How to cite (IJASEIT) :
Son, Lovely, et al. “Empirical Evaluation of Variation of Orifice Blocking Ratio in a Tuned Liquid Column Damper Using Frequency Response Function Measurement”. International Journal on Advanced Science, Engineering and Information Technology, vol. 8, no. 2, Mar. 2018, pp. 489-94, doi:10.18517/ijaseit.8.2.4163.
Tuned liquid column damper (TLCD) is a simple technique used to increase the structure resistance to the external load. This type of damper can effectively decrease the structure response when the TLCD parameters such as the natural frequency and damping factor are well selected. Even though several TLCD models have been proposed and many algorithms to optimize the TLCD parameters have been developed. However, it is very little research has been conducted to evaluate the TLCD damping factor experimentally. A simple method for adjusting the TLCD damping factor empirically is by varying the orifice blocking ratio. In this research, 5 types of blocking ratio were trialled in the TLCD. They were without orifice and with 2, 4, 6 and 8 18 mm diameter orifices. The TLCD is positioned at the second floor of a Two-DOF shear structure. A frequency response function showing the ratio between the response magnitude and the excitation force on the structure in the frequency domain was recorded for each trial. The results show that the TLCDs with orifices damped vibrations more effectively than the one without orifice. The larger the blocking ratio, the larger the TLCD damping factor. Two 18 mm orifices were insufficient to damp the vibration as the blocking ratio is too large and TLCD is less responsive to the vibrations. The optimum condition of a U-Shaped TLCD blocking ratio was found to be 70.77% which corresponded to 4 holes of 18 mm orifice diameter. This type of TLCD dampened up to 80.04% of the vibration magnitude.

Authors who publish with this journal agree to the following terms:

    1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
    2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
    3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).