Robust Features for Elbow Joint Angle Estimation Based on Electromyography

- Triwiyanto (1), Oyas Wahyunggoro (2), Hanung Adi Nugroho (3), - Herianto (4)
(1) Department of Electrical Engineering & Information Technology, Faculty of Engineering, Universitas Gadjah Mada, Grafika No. 2, Yogyakarta, Indonesia
(2) Department of Electrical Engineering & Information Technology, Faculty of Engineering, Universitas Gadjah Mada, Grafika No. 2, Yogyakarta, Indonesia
(3) Department of Electrical Engineering & Information Technology, Faculty of Engineering, Universitas Gadjah Mada, Grafika No. 2, Yogyakarta, Indonesia
(4) Department of Electrical Engineering & Information Technology, Faculty of Engineering, Universitas Gadjah Mada, Grafika No. 2, Yogyakarta, Indonesia
Fulltext View | Download
How to cite (IJASEIT) :
Triwiyanto, -, et al. “Robust Features for Elbow Joint Angle Estimation Based on Electromyography”. International Journal on Advanced Science, Engineering and Information Technology, vol. 8, no. 5, Oct. 2018, pp. 1956-61, doi:10.18517/ijaseit.8.5.6495.
A noisy environment is a major problem which has to be resolved to get a good performance in the estimation. A robust feature is important in order to obtain an accurate position of the elbow joint from the electromyography (EMG) signal. The objective of this research is to modify and assess the time domain features which robust against the white Gaussian noise. In this work, the EMG signal (from biceps) contaminated by artificial white Gaussian noise was extracted using twelve standard time domain features and one modified feature. The threshold of the modified feature (MYOPM) was calculated based on the root mean square (RMS) of the contaminated EMG signal. The linear Kalman filter was used to refine the EMG features and to improve the estimation. The robustness of the features was calculated using the root mean square error (RMSE). Based on the RMSE values, it shows that the proposed feature MYOPM is the most robust feature (the lowest median RMSE of 9º) for the signal to noise ratio (SNR) ranged between 17.96 and 60 dB, compared with the others’ features. The mean RMSE of the MYOPM feature improves by 27.91% from the prior feature (MYOP).

H. Lee, W. Kim, J. Han, and C. Han, “The technical trend of the exoskeleton robot system for human power assistance,” International Journal of Precision Engineering and Manufacturing, vol. 13, no. 8. pp. 1491-1497, 2012.

S. Thongpanja, A. Phinyomark, F. Quaine, Y. Laurillau, C. Limsakul, and P. Phukpattaranont, “Probability Density Functions of Stationary Surface EMG Signals in Noisy Environments,” IEEE Trans. Instrum. Meas., vol. 65, no. 7, pp. 1547-1557, Jul. 2016.

P. McCool, G. D. Fraser, A. D. C. Chan, L. Petropoulakis, and J. J. Soraghan, “Identification of contaminant type in surface electromyography (EMG) signals,” IEEE Trans. Neural Syst. Rehabil. Eng., vol. 22, no. 4, pp. 774-783, 2014.

R. H. Chowdhury, M. B. I. Reaz, M. A. B. M. Ali, A. a a Bakar, K. Chellappan, and T. G. Chang, “Surface electromyography signal processing and classification techniques.,” Sensors (Basel)., vol. 13, no. 9, pp. 12431-12466, 2013.

L. Smital, M. Ví­tek, J. Kozumplí­k, and I. Provazní­k, “Adaptive wavelet wiener filtering of ECG signals,” IEEE Trans. Biomed. Eng., vol. 60, no. 2, pp. 437-445, 2013.

[6] S. Thongpanja, A. Phinyomark, C. Limsakul, and P. Phukpattaranont, “A robust measure of probability density function of various noises in electromyography (EMG) signal acquisition,” 2015 7th Int. Conf. Knowl. Smart Technol., no. January 2015, pp. 1-6, 2015.

A. Phinyomark, C. Limsakul, and P. Phukpattaranont, “A Novel Feature Extraction for Robust EMG Pattern Recognition,” J. Comput., vol. 1, no. 1, pp. 71-80, 2009.

M. Zardoshti-Kermani, B. C. Wheeler, K. Badie, and R. M. Hashemi, “EMG feature evaluation for movement control of upper extremity prostheses,” IEEE Trans. Rehabil. Eng., vol. 3, no. 4, pp. 324-333, 1995.

G. Guo, M. Mandal, and Y. Jing, “A robust detector of known signal in non-Gaussian noise using threshold systems,” Signal Processing, vol. 92, no. 11, pp. 2676-2688, 2012.

M. Asghari Oskoei and H. Hu, “Myoelectric control systems-A survey,” Biomed. Signal Process. Control, vol. 2, no. 4, pp. 275-294, 2007.

M. a. Oskoei and H. H. H. Hu, “Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb,” IEEE Trans. Biomed. Eng., vol. 55, no. 8, pp. 1956-1965, 2008.

D. Tkach, H. Huang, and T. A. Kuiken, “Study of stability of time-domain features for electromyographic pattern recognition,” J. Neuroeng. Rehabil., vol. 7, no. 1, p. 21, 2010.

Z. Li, B. Wang, F. Sun, C. Yang, Q. Xie, and W. Zhang, “SEMG-based joint force control for an upper-limb power-assist exoskeleton robot,” IEEE J. Biomed. Heal. Informatics, vol. 18, no. 3, pp. 1043-1050, 2014.

Q. Ding, X. Zhao, A. Xiong, and J. Han, “A Novel Motion Estimate Method of Human Joint with EMG-Driven Model,” in 2011 5th International Conference on Bioinformatics and Biomedical Engineering, 2011, no. 1, pp. 1-5.

Triwiyanto, O. Wahyunggoro, H. A. Nugroho, and Herianto, “An investigation into time domain features of surface electromyography to estimate the elbow joint angle,” Adv. Electr. Electron. Eng., vol. 15, no. 3, 2017.

Li Tan & Jean Jiang, Digital Signal Processing: Fundamental and Applications, 1st ed., vol. 70, no. 3. California: Elsevier, 2008.

A. Phinyomark, P. Phukpattaranont, and C. Limsakul, “Feature reduction and selection for EMG signal classification,” Expert Syst. Appl., vol. 39, no. 8, pp. 7420-7431, 2012.

Mohinder S. Grewal; Angus P. A, Kalman Filtering Theory and Practice Using MATLAB, Third., vol. 53, no. 9. Canada, 2008.

Triwiyanto, O. Wahyunggoro, H. A. Nugroho, and Herianto, “Effect of window length on performance of the elbow-joint angle prediction based on electromyography,” J. Phys. Conf. Ser., vol. 853, p. 12014, May 2017.

T. Triwiyanto, O. Wahyunggoro, H. A. Nugroho, and H. Herianto, “Evaluating the performance of Kalman filter on elbow joint angle prediction based on electromyography,” Int. J. Precis. Eng. Manuf., vol. 18, no. 12, pp. 1739-1748, Dec. 2017.

Authors who publish with this journal agree to the following terms:

    1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
    2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
    3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).